Door with photocell integratedwith the safety edge to protect the operator in the descending phase.
Technical specifications
Useful width (standard) | 700 / 3500 mm |
Useful height (standard) | 2200 mm |
Opening way | Vertical |
Roll -up Shutter | Shutter cloth (available colours: yellow, orange, blue, red, white, black) |
Visual (optional) | Transparent panel or anti-UV in compliance with EN 1598 |
Self-supporting upright | Stainless Steel with epoxy-polyester powder coated sheet metal casing |
Roll | Stainless Steel |
Roll carter | Metal Sheet painted with epoxy-polyester powders |
Support edge profile | Anodized aluminum |
ront anti-intrusion wall (optional) | Metal Sheet painted with epoxy-polyester powders |
Drive unit | GFA Elektromaten engine |
Engine side | Left/Right |
Opening / closure | 1 m/sec |
Control unit
Power | 0,75 kW |
Fuse protection | 10A |
Control voltage | 24V dc |
Protection | Ip55 |
Power supply | 400V, 3phases + ground |
Frequency | 50Hz |
Number of standard cycles | 2 Cycles/min |
Safety
Standard | Electrical safety edge |
Standard | Crank opening in an emergency |
Standard | Reducer fall protection system |
Optional | Sliding photocell integrated with the sheet to protect the operator in the descending phase + Shockproof edge (no electricity) |
Optional | Sliding photocell integrated with the sheet to protect the operator in the descending phase + Sliding photocell integrated with the sheet to protect the operator in the ascending phase + Shockproof edge (no electricity) |
Optional | Sliding photocell integrated with the sheet to protect the operator in the descending phase + Sliding photocell integrated with the sheet to protect the operator in the ascending phase + Electrical safety edge |
Further specifications
N. 1 Safety relay switch for closing the category 4 door, pl and en iso 13849-1, sil 3 en 62061N. 1 Switch a relais di sicurezza per la chiusura della porta categoria 4, pl e en iso 13849-1, sil 3 en 62061 |
1-port profinet fieldbus inserted in the electrical panel |
ILME connector for connection between motor and control unit (for brake power cable) |
Door/ electrical panel connection with ILME connector cable |
Door/ electrical panel connection cable standard length 5mt |